613 97283111

Flow Measurement

BFS25 BFS25 Flow switch

Advantages:
Suitable for pipe sizes from 1″ to 12″ diameter
Standard 1″ BSP fitting
3.3 to 4,830 l/min switch adjustment ranges
4 x paddle sizes supplied with each switch.
Brass or stainless steel body
Protected to IP65
15Amp Switching current 240/50
This economical flow switch is designed for pump protection in the irrigation and industrial pump industry, its simple design and robust construction makes it Ideal for the OEM use.

pdf

pha BFS EO1

Features

This is a Electronic flow switch based on the thermal principle.
The insertion sealed probe contains 2 resistors one is heated
and the other is not, this is known as the benchmark resistor.
When the fluid flows the heat is dissipated and the detecting
resistor, resistance remains stable. When the Flow stops the
resistance value is altered this measurement is used to determine
flow or no flow.
Advantages of this type of unit are maintenance free installation
no moving parts and high working pressure.

pdf

Vrate2_1 EZ-VIEW Flowmeters

Superior Readability
The extra long 31/2″ (90 mm) scale provides excellent flow rate measuring resolution compared to competitive products.
Dual measuring units – U.S. (GPM) and Metric (LPM) graduations are standard.
Compact and Rugged
EZ-VIEW’s tough polysulphone construction measures less than 125 mm (5 inches) long and 38 mm (11/2 inches) in diameter
suitable for permanent installation in lubrication, cooling and hydraulic pump case drain systems.
Mount in Any Orientation
EZ-VIEW will provide stable, accurate readings when mounted in any piping orientation.
Fluid Inspection.
The transparent body of the meter permits visual inspection of fluid conditions.
Excessive aeration, contamination or discolouration can be diagnosed “at a glance”. Ez-View Flow-meters.
Patented Sensing Method.
EZ-VIEW’s Sharp edge orifice plate sensing method assures measurement accuracy of better than 95% of actual flow rates – even with variable fluid parameters.
The EZ-VIEW flowm-eter is supplied with the Installation Instructions.
Maintainable
Has only one moving component – sharp edge orifice plate spring loaded!
Can be easily cleaned or replaced.
Accurate.
pdf

FMV_1 Acrylic Flow-meters

Baccara Automation Control have a comprehensive range of plastic flow-meters, based on the variable area principle, which are corrosion resistant, extremely accurate, simple to use and maintain, and possess considerable impact resistance.
Baccara can provide technical advice on the variety of metering-tube and float materials which are suitable for neutral and corrosive media.
Special scales may be necessary for certain media and operating environments. Baccara can advise and arrange for the supply of such scales if required.
Baccara can also advise on and provide a variety of accurate limit switches which may be integrated with the flow-meter. The function of the limit switches is neither effected by the working pressure, nor by the conductivity, concentration or density of the medium.
Flow-meters may be ordered Specially Equipped for harsh environments. Baccara Automation Control can advise you on your specific requirements.
Uses:
Reverse Osmosis Equipment.
D.I. Water & ultra-pure water systems.
Film Processing Equipment.
Pollution Monitoring & Control Equipment.
Chemical Procession Equipment.
Food Processing and Piping Components.
Filtration Equipment.
Chemigation
Electronic Component & Microchip Procession Equipment.

pdf

0001 KTW Turbine ½” through to 2 “

Ideal for irrigation or industrial water applications
Pulse output
Accuracy 1% of full scale
Chemically resistant PVC construction
Loop Powered application 10 to 36 volt supply

pdf

flow2_1 Titan Displaying 800 Series

Low cost
4 digit rate/total display
PVDF body
1- 2% FSD
Sapphire bearings
Hall effect sensor
6 Flow ranges
Auto cal feature
Pulse output
10 Bar rating
8 mm hose or 3/8″ tails*
0.1% Repeatability
8 to 12 V dc
55°C Max
* John Guest style connections

Ideal for
Laboratory tests
Cooling equipment
Semiconductor plant
OEM applications
Typical Applications Displaying 800 Series

pdf

flow3_1 Titan Flow Transducer

Advantages
Economical
Acetal body
1½% FSD
Sapphire bearings
Optical sensing
2 Flow ranges
Pulse output
15 Bar rating
Nitrile seal
15mm fittings
0.25% Repeatability

Various power options
70°C Max
Flow switch option
IP 54

Ideal for
Drink dispensing
Showers
Cooling equipment
Dishwashers
Low viscosity fluids
OEM applications

pdf

flow4_1 Titan Oval gear flowmeters

Positive displacement
Pressures up to 670 Bar
Viscosities -1 to 10,000 cP
Low pressure loss
0.1% Repeatability
Flows from 1mL/Min (150cP)
Wide rangability
Inherently linear
Hazardous area versions
Temp to 200oC (80oC std.)
Reed switch or Hall effect
0.25, 0.5 and 1% accuracies
Excellent chemical resistance
Compact design
In house designed & manufactured
Choice of materials
Bi-directional
Up to 500 L/Min Oval Gear Flometers

pdf

flow1_1 FT2 Optical Detection

Economical
PPS body
1- 2% FSD or ±0.75% reading*
Sapphire bearings
Optical sensor
9 Flow ranges
Pulse output
15 Bar rating
Viton seal as std.
Choice of fittings
0.1% Repeatability
5 or 7.5 to 24 V dc
80°C Max

*When used with Metra-smart instrument.

Ideal for
Laboratory tests
Water treatment
Cooling equipment
Semiconductor plant
Engine test FT2 Optical

pdf

Lake_Flow Lake Flow Monitors

Advantages:
Rugged Construction.
Monitor liquid flows up to 150 GPM (560 LPM)
Pressures up to 3500 PSI (240 Bar)
Temperatures up to 600°F (316 C)
No electrical connections
Good viscosity stability.
No flow straighteners needed.
Opaque or clear fluids.
Aluminum, brass or stainless steel material.

pdf

vh325 Paddle-type Flow Switch

Advantages
Applicable for pipe sizes between 8 and 200mm.
Flow control range between 0.5 l/min and 200 m3Wide adjustment range.
Maximum pressure up to 250 bar/3.600 psi.
Maximum temperature 125°C/257°F.
Reliable and simple warning device for flow and level.
Optimal price/performance ratio.
Safe operations under heavy conditions.
More than 500 different types for almost any application.
Minimal pressure drop.
Applicable for fluids (gas and liquids).
High repeatability.

Available Materials brass
brass (nickel or teflon plated)
stainless steel
plastic (PPO Noryl GFS 30/GFN 3)
other materials on request.

Typical Applications
heat exchangers
cleaning systems
compressors
water conditioning systems
air conditioning systems
cooling systems
hot water/heater systems
lubrication systems
fire sprinkler systems
irrigation piping Paddle Type Flow Switch
pdf

plasfm Plastic Flowmeters

Baccara Automation Control have a comprehensive range of plastic flowmeters, based on the variable area principle, which are corrosion resistant, extremely accurate, simple to use and maintain, and which possess considerable impact resistance. Baccara can provide technical advice on the variety of metering-tube and float materials which are suitable for neutral and corrosive media.

Special scales may be necessary for certain media and operating environments. Baccara can advise and arrange for the supply of such scales if required.

Baccara can also advise on and provide a variety of accurate limit switches which may be integrated with the flowmeter. The function of the limit switches is neither effected by the working pressure, nor by the conductivity, concentration or density of the medium.

Flowmeters may be ordered Specially Equipped for harsh environments. Baccara Automation Control can advise you on your specific requirements.

Uses
Reverse Osmosis Equipment
D.I. Water & ultrapure water systems
Film Processing Equipment
Pollution Monitoring & Control Equipment
Chemical Procession Equipment
Food Processing and Piping Components
Filtration Equipment
Chemigation
Electronic Component & Microchip Procession Equipment

Accessories / Options
Special Scales
High Flow Alarm
Low Flow Alarm
Special Connectors Plastic Flow Meter
pdf

EFM_25_003_1_1_1_1_1 Electronic Oil or Fuel Monitor

Battery Powered Turbine features low power CPU
core technology 1″ BSP- (18 > 180) L/min
5 Digit LCD Display 0.01 > 99999.
2 Cumulative Totals by reset button.
Battery Life up to 9000hrs or 2 years.
Accuracy :1%
Settable Display Calibration: US/Gal. pints or litres
Onsite Calibration.
Can be supplied as integrated fuel filler nozzle.

pdf