Electronic oil or Fuel Monitor
New From Baccara !
Battery Powered Turbine features low power CPU core Technology 1" BSP- (18 > 180) L/min
5 Digit LCD Display 0.01 > 99999.2 Cumulate Totals by reset buttonBattery Life up to 9000hrs or 2 yearsAccuracy :1%Settable Display Calibration: US/Gal or Litres, pintsOnsite CalibrationCan be supplied as integrated fuel filler nozzle
Baccara Can advise
|
 |
| Top |
 |
Oval gear flowmeters
Positive displacement Pressures up to 670 Bar Viscosities -1 to 10,000 cP Low pressure loss 0.1% Repeatability Flows from 1mL/Min (150cP) Wide rangability Inherently linear Hazardous area versions Temp to 200oC (80oC std.) Reed switch or Hall effect 0.25, 0.5 and 1% accuracies Excellent chemical resistance Compact design In house designed & manufactured Choice of materials Bi-directional Up to 500 L/Min |
 |
Displaying 800 Series
Low cost  4 digit rate/total display  PVDF body  1- 2% FSD  Sapphire bearings  Hall effect sensor  6 Flow ranges  Auto cal feature  Pulse output  10 Bar rating  8 mm hose or 3/8" tails*  0.1% Repeatability  8 to 12 V dc  55°C Max  * John Guest style connections
Ideal for  Laboratory tests  Cooling equipment  Semiconductor plant  OEM applications  Typical Applications |
 |
FT2 Optical Detection
Economical PPS body 1- 2% FSD or ±0.75% reading* Sapphire bearings Optical sensor 9 Flow ranges Pulse output 15 Bar rating Viton seal as std. Choice of fittings 0.1% Repeatability 5 or 7.5 to 24 V dc 80°C Max *When used with Metra-smart instrument.
Ideal for Laboratory tests Water treatment Cooling equipment Semiconductor plant Engine test |
 |
Flow Tranducer
Advantages Economical Acetal body 1½% FSD Sapphire bearings Optical sensing 2 Flow ranges Pulse output 15 Bar rating Nitrile seal 15mm fittings 0.25% Repeatability Various power options 70°C Max Flow switch option IP 54
Ideal for Drink dispensing Showers Cooling equipment Dishwashers Low viscosity fluids OEM applications |
 |
Paddle-type Flow Switch
Advantages Applicable for pipe sizes between 8 and 200mm. Flow control range between 0.5 l/min and 200 m3Wide adjustment range. Maximum pressure up to 250 bar/3.600 psi. Maximum temperature 125°C/257°F. Reliable and simple warning device for flow and level. Optimal price/performance ratio. Safe operations under heavy conditions. More than 500 different types for almost any application. Minimal pressure drop. Applicable for fluids (gas and liquids). High repeatability.
Available Materials brass brass (nickel or teflon plated) stainless steel plastic (PPO Noryl GFS 30/GFN 3) other materials on request.
Typical Applications heat exchangers cleaning systems compressors water conditioning systems air conditioning systems cooling systems hot water/heater systems lubrication systems fire sprinkler systems irrigation piping |
 |
Lake Flow Monitors
Advantages Rugged Construction Monitor liquid Flows up to 150 GPM Pressures up to 3500 psi Temperatures up to 600°F No electrical connections Good Viscosity Stability No Flow Straighteners needed Opaque or Clear Fluids Aluminium, Brass or Stainless Steel |
 |
BFS25 Flow switch
Advantages data sheet attached Suitable for pipe sizes from 1" to 12" diameter Standard 1" BSP fitting 3.3 to 4,830 l/min switch adjustment ranges 4 x paddle sizes supplied with each switch Brass or stainless steel body Protected to IP65 Product Description 15Amp Switching current 240/50
New to the Baccara range this economical flow switch is designed for pump protection in the irrigation and industrial pump industry its simple design and robust construction makes it Ideal for the OEM user |
 |
Plastic Flowmeters
Baccara Automation Control have a comprehensive range of plastic flowmeters, based on the variable area principle, which are corrosion resistant, extremely accurate, simple to use and maintain, and which possess considerable impact resistance. Baccara can provide technical advice on the variety of metering-tube and float materials which are suitable for neutral and corrosive media.
Special scales may be necessary for certain media and operating environments. Baccara can advise and arrange for the supply of such scales if required.
Baccara can also advise on and provide a variety of accurate limit switches which may be integrated with the flowmeter. The function of the limit switches is neither effected by the working pressure, nor by the conductivity, concentration or density of the medium.
Flowmeters may be ordered Specially Equipped for harsh environments. Baccara Automation Control can advise you on your specific requirements.
Uses Reverse Osmosis Equipment D.I. Water & ultrapure water systems Film Processing Equipment Pollution Monitoring & Control Equipment Chemical Procession Equipment Food Processing and Piping Components Filtration Equipment Chemigation Electronic Component & Microchip Procession Equipment
Accessories / Options Special Scales High Flow Alarm Low Flow Alarm Special Connectors |
 |
Acrilic Flowmeters
Baccara Automation Control have a comprehensive range of plastic flowmeters, based on the variable area principle, which are corrosion resistant, extremely accurate, simple to use and maintain, and which possess considerable impact resistance. Baccara can provide technical advice on the variety of metering-tube and float materials which are suitable for neutral and corrosive media.
Special scales may be necessary for certain media and operating environments. Baccara can advise and arrange for the supply of such scales if required.
Baccara can also advise on and provide a variety of accurate limit switches which may be integrated with the flowmeter. The function of the limit switches is neither effected by the working pressure, nor by the conductivity, concentration or density of the medium. |
 |
Flowmeters may be ordered Specially Equipped for harsh environments. Baccara Automation Control can advise you on your specific requirements.
Uses Reverse Osmosis Equipment D.I. Water & ultrapure water systems Film Processing Equipment Pollution Monitoring & Control Equipment Chemical Procession Equipment Food Processing and Piping Components Filtration Equipment Chemigation Electronic Component & Microchip Procession Equipment |
EZ-VIEW Flowmeters
Superior Readability The extra long 31/2" (90 mm) scale provides excellent flow rate measuring resolution compared to competitive products. Dual measuring units - U.S. (GPM) and Metric (LPM) graduations are standard.
Compact and Rugged EZ-VIEW's tough polysulphone construction measures less than 125 mm (5 inches) long and 38 mm (11/2 inches) in diameter suitable for permanent installation in lubrication, cooling and hydraulic pump case drain systems.
Mount in Any Orientation EZ-VIEW will provide stable, accurate readings when mounted in any piping orientation.
Fluid Inspection The transparent body of the meter permits visual inspection of fluid conditions.
Excessive aeration, contamination or discoleration can be diagnosed "at a glance". |
 |
Patented Sensing Method EZ-VIEW's Sharp edge orifice plate sensing method assures measurement accuracy of better than 95% of actual flow rates - even with variable fluid parameters. The EZ-VIEW flowmeter is supplied with the Installation Instructions.
Maintainable Has only one moving component - sharp edge orifice plat spring loaded! Can be easily cleaned or replaced without removing the sensor from the piping.
Accurate Dynamic measuring technique will not falsely indicate flow rate when none is present.
Tough Circuitry is hermetically encapsulated within the sensor body for optimum performance, even in the harshest environments.
Easy Operation Comes factory calibrated to your flow range specifications. Simply plumb and apply power. Integrated circuitry allows unit to be directly connected to your analog acquisition cards, chart recorders or other monitoring instruments. No need to mount external conditioning circuitry.
Standard sensor interface is a 2-wire, 4-20mA current loop that can be transmitted for several thousand feet an a low cost wire without degradation. Voltage and pulse outputs are available.
Versatility Ideal for measuring flow rates in cooling and lubrication circuits, HVAC systems, aggressive chemical metering and batching systems. |
|
|
|
|
 |
 |
|
|
|